Continue to Basket

Galvanic Isolator F-Type, 5-2400 MHz

Product Code: PROGALISOL11

  • Legal requirement for earthing
  • F-Type connections
Galvanic Isolator F-Type, 5-2400 MHz
Galvanic Isolator F-Type, 5-2400 MHz
£13.52 Inc VAT
Lifetime guarantee on internally installed products Includes technical support

Payment methods accepted

Mastercard Visa AMEX PayPal Discover Apple Pay Google Pay

Product Description

Galvanic Isolator F-Type - breaks ground loops between two units sharing a ground conductor -5/2400MHz

Galvanic isolation is used where two or more electric circuits must communicate, but their grounds may be at different potentials. It is an effective method of breaking ground loops by preventing unwanted current from flowing between two units sharing a ground conductor. Galvanic isolation is also used for safety, preventing accidental current from reaching ground through a person's body.

The PROGALISOL11 is therefore a product providing a method to isolate system earthing between individual buildings whereby a single head-end is being used to supply multiple buildings. Under current regulations galvanic isolation is legally required to be added on each signal cable line link between each building. Full earthing must then be provided for each building within that building strictly on an individual basis. This ensures that there is no dangerous common earth across a system over several buildings. This is an item which is simple and speedy to install.

Features:

  • F-Type connections for input and output.
  • Covers frequency 5 - 2400MHz.
  • Directional flow indicators.
  • Easy and speedy to install.
  • Surge Protection: 2KVDC, 3s, 1mA.

Product Description

Galvanic Isolator F-Type - breaks ground loops between two units sharing a ground conductor -5/2400MHz

Galvanic isolation is used where two or more electric circuits must communicate, but their grounds may be at different potentials. It is an effective method of breaking ground loops by preventing unwanted current from flowing between two units sharing a ground conductor. Galvanic isolation is also used for safety, preventing accidental current from reaching ground through a person's body.

The PROGALISOL11 is therefore a product providing a method to isolate system earthing between individual buildings whereby a single head-end is being used to supply multiple buildings. Under current regulations galvanic isolation is legally required to be added on each signal cable line link between each building. Full earthing must then be provided for each building within that building strictly on an individual basis. This ensures that there is no dangerous common earth across a system over several buildings. This is an item which is simple and speedy to install.

Features:

  • F-Type connections for input and output.
  • Covers frequency 5 - 2400MHz.
  • Directional flow indicators.
  • Easy and speedy to install.
  • Surge Protection: 2KVDC, 3s, 1mA.

Technical Specification

Width

25mm

Depth

78mm

Height

25mm

Weight

0.06kg

Fred
19/04/2024

Great service and company to deal with

Robert
15/04/2024

I researched for many TV aerials and my friend who was ex aerial rigger recommended me Blake aerials as you can’t go wrong with them that was his words and it was true


13/04/2024

Ok until Blake sold me an item they didn't have in stock ...

Philip
05/04/2024

Very good service as a company, very let down by sending out parts poorly packaged, must cost a fortune sending replacements out..

Philip
05/04/2024

Seem fine

Google Company Reviews

Neil Provis
Neil Provis
07/09/2024

All Arrials I purchased were installed at BBC Radio Gloucester with great results Will be purchasing more soon Thank you Blake Team DAB @ FM

Jamie Smith
Jamie Smith
03/09/2024

I used the online customer support system used by Blake UK for advice regarding my intended installation and got very quick and helpful advice on what would suit me best….this was honest advice as I was thinking of purchasing more expensive items that would be unnecessary and also possibly even detrimental to my intended installation. My order was received very quickly and although there had been a small mistake regarding the length of cable I had ordered this was immediately rectified by Blake UK again using their online messaging system. Personally I cannot fault Blake UK and would be very happy to recommend them to anyone, a very helpful and professional business, thank you.

Damien Baker
Damien Baker
31/08/2024

As described and arrived quickly. Well packaged

Peter Jackson
Peter Jackson
30/08/2024

Rapid and extremely efficient service. Ordered in the afternoon and delivered next morning. Exceptional service and excellent products which work impeccable. Would give this Company 11/10!

Graham Pink
Graham Pink
20/08/2024

Very helpful

£13.52 Inc VAT
Lifetime guarantee on internally installed products Includes technical support

Payment methods accepted

Mastercard Visa AMEX PayPal Discover Apple Pay Google Pay

Product Description

Galvanic Isolator F-Type - breaks ground loops between two units sharing a ground conductor -5/2400MHz

Galvanic isolation is used where two or more electric circuits must communicate, but their grounds may be at different potentials. It is an effective method of breaking ground loops by preventing unwanted current from flowing between two units sharing a ground conductor. Galvanic isolation is also used for safety, preventing accidental current from reaching ground through a person's body.

The PROGALISOL11 is therefore a product providing a method to isolate system earthing between individual buildings whereby a single head-end is being used to supply multiple buildings. Under current regulations galvanic isolation is legally required to be added on each signal cable line link between each building. Full earthing must then be provided for each building within that building strictly on an individual basis. This ensures that there is no dangerous common earth across a system over several buildings. This is an item which is simple and speedy to install.

Features:

  • F-Type connections for input and output.
  • Covers frequency 5 - 2400MHz.
  • Directional flow indicators.
  • Easy and speedy to install.
  • Surge Protection: 2KVDC, 3s, 1mA.